Skip to content

Sample gallery

Every sample is one click away. Open it in the editor, run it, or save your own modified copy.

AC-Fault

A three-phase-to-ground fault applied to a transmission line, then cleared.

Open in simulator →

BergeronDemo

A travelling-wave (Bergeron) transmission line showing how a step propagates and reflects.

Open in simulator →

Active-Vs-Reactive-Power

A ready-to-run NumaSim sample circuit.

Open in simulator →

Buck

A step-down (buck) DC–DC converter switching at a fixed duty cycle.

Open in simulator →

Control Loop Delay

A stopwatch for the engine: a square-wave command opens and closes a breaker, and the load current comes back into the control domain, so you can count the exact number of time steps each domain crossing costs.

Open in simulator →

Full Bridge Rectifier

A full-bridge (Graetz) rectifier that converts AC to DC with four diodes.

Open in simulator →

Generator Controls Disturbance

A synchronous machine with IEEE DC1A excitation and a TGOV1 governor riding through a 100 ms bolted three-phase fault.

Open in simulator →

Half Bridge Rectifier

A half-wave rectifier that turns an AC source into a rough DC level.

Open in simulator →

Induction Machine Motoring

A 1 MVA, 480 V induction machine driving a constant 0.4 pu load torque — the motoring operating point.

Open in simulator →

Line Open Short

The two extreme line terminations — open and short — showing voltage doubling and cancellation.

Open in simulator →

Multirate Counter

Free-running digital counters ticking at different rates, organized with subsystems.

Open in simulator →

Pwm Power Control

A closed-loop PWM power controller that holds its output at a setpoint with a PID.

Open in simulator →

Pwm Subsystem

A closed-loop PWM power regulator with its controller wrapped in a reusable Subsystem.

Open in simulator →

Rc Charging

Charging of a series R-C circuit — capacitor voltage rising toward the source with time constant τ = RC.

Open in simulator →

Rl Step Response

Step response of a series R-L circuit — current rising toward V/R with time constant τ = L/R.

Open in simulator →

Rlc Series Step

Step response of an underdamped series R-L-C circuit — ringing and overshoot before settling.

Open in simulator →

Short Line Pi

A line short enough that its travel time falls below the time step, so it is modelled as a lumped π section.

Open in simulator →

Sync Machine Load

A 100 MVA synchronous machine on a stiff 13.8 kV bus, exporting into a local PQ load.

Open in simulator →

Sync Machine Short Circuit

A bolted three-phase fault on the terminals of an unloaded machine — the test that

Open in simulator →

Transformer Energization

No-load energization of a saturable 230/115 kV transformer — magnetizing inrush and its decay.

Open in simulator →

Transformer Sc Test

The classic short-circuit test: shorted secondary, reduced primary voltage, and a

Open in simulator →

Voltage Divider

A two-resistor voltage divider — the smallest circuit in the library and a good first run.