Skip to content

Resistor ​

Single-phase ideal resistor. Implements Ohm's law v = R i. The most common passive element — use for damping, sensing, and load modelling.

Category: Single-Phase / Passive

Ports ​

NameDirectionValue typeNotes
N1electricaldouble
N2electricaldouble

Parameters ​

Config ​

NameLabelTypeDefaultUnitsDescription
resistanceRdouble1Ohms (Ω, kΩ, pu, S)Resistance value. Pick a unit from the dropdown; pu / Siemens conversions read the bases from the Units tab.
measure_currentMeasure currentenum (Off / On)0—Emit branch current as a simulator observable.

Current Monitoring ​

NameLabelTypeDefaultUnitsDescription
current_nameCurrent namestringI—Signal name for the measured branch current. Change the default `I` when you have multiple measured components — duplicate ids collide.

Units ​

NameLabelTypeDefaultUnitsDescription
S_baseS_base (MVA)double100—System base apparent power in MVA. Used by `pu` impedance / admittance conversions in this component's `computations` block.
V_baseV_base (kV)double230—Base RMS line-to-line voltage in kV. Used by `pu` impedance / admittance conversions in this component's `computations` block.

Observables ​

SignalTypeDefault nameEnableDescription
branchCurrentsignalfrom current_namemeasure_currentBranch current through the resistor (A).

Used in samples ​