Appearance
Wind Turbine
Variable-pitch wind turbine rotor: steady-state aerodynamic power from wind speed, generator speed and blade pitch, delivered as shaft torque in pu of the generator. Mechanical power is P = kp·(Cp/Cpmax)·(v/vbase)³ pu of the nominal power, with the generic performance coefficient Cp(λ, β) = c1(c2/λi − c3β − c4)e^(−c5/λi) + c6λ and 1/λi = 1/(λ + 0.08β) − 0.035/(β³ + 1); the tip-speed ratio is λ = λnom·(ω/ωbase)/(v/vbase), where λnom is the ratio at which Cp(λ, 0) peaks. Torque is Tm = P·Pnom/(Sgen·ω). A power-limiting pitch controller (PI on P − Plim with anti-windup, then a rate-limited servo) raises the pitch above rated power and rests on the minimum pitch below it; a fixed-pitch mode holds a constant angle. The rotor inertia is not inside: wire Tm to the synchronous or induction machine shaft (a two-mass shaft puts it on the turbine mass) and the machine speed back to the speed input. Use it as the prime mover of a Type-3 or Type-4 wind turbine.
Category: Control / Turbine
Overview
The Wind Turbine block is the aerodynamic rotor of a variable-speed wind turbine. It reads the wind speed and the generator rotor speed and outputs the mechanical torque that drives the generator, together with the blade pitch angle.
The rotor power follows the standard power-coefficient curve speed output to ω and the block's Tm to the machine's Tm input.
Power coefficient
The power coefficient is the generic six-constant curve
with
Per-unit rotor model
All quantities are per unit: wind on the base wind speed, speed on the base rotor speed, and power on the nominal mechanical power
When
Pitch control
With Pitch mode = Power limiting a PI controller acts on the power error
Pitch mode = Fixed holds
The pitch starts at Initial pitch. Start it near the expected operating pitch to avoid a power overshoot at the beginning of a run.
Example operating point
With base wind 11 m/s, base speed 1 pu and
Wiring
- v ← wind speed (m/s), for example a Constant or a Time Table for gusts and ramps.
- ω ← the machine's
speedoutput (pu). - Tm → the machine's
Tminput (pu on the machine base). - β → optional, for plotting or downstream logic (degrees).
Enable the options on the Monitoring tab to record the mechanical power, the pitch, and
Ports
| Port | Kind | Signal | Notes |
|---|---|---|---|
wind | Control input | Real | |
speed | Control input | Real | |
Tm | Control output | Real | |
pitch | Control output | Real |
Parameters
Turbine
| Parameter | Type | Default | Units | Description | ID |
|---|---|---|---|---|---|
| Pnom | Number | 2 | MW (also W, kW) | Nominal mechanical output power of the turbine. The mechanical power P is in pu of this value. | p_nom |
| Sgen | Number | 2 | MVA (also VA, kVA) | Rated power of the generator the turbine drives. The torque output is in pu of that machine's rated torque, so it wires straight to the machine's Tm input. | s_gen |
| Base wind speed | Number | 12 | m/s (also km/h) | Base wind speed of the per-unit system. At this wind speed and the base rotational speed, with zero pitch, the turbine delivers the power gain kp. | base_wind |
| kp (power at base wind) | Number | 0.73 | — | Maximum power at the base wind speed, in pu of the nominal power (≤ 1). | power_gain |
| Base rotational speed | Number | 1.2 | — | Generator speed (pu of synchronous speed) at which the turbine reaches its maximum power at the base wind speed, i.e. where λ = λnom. | base_speed |
Pitch
| Parameter | Type | Default | Units | Description | ID |
|---|---|---|---|---|---|
| Pitch | Choice: Power limiting / Fixed | Power limiting | — | Power limiting = a PI on the power error raises the pitch when the power exceeds Plim and rests on the minimum pitch below it. Fixed = hold the pitch at the fixed angle. | pitch_mode |
| Fixed pitch | Number | 0 | ° (also rad) | Blade pitch held in Fixed mode. | pitch_fixed |
| Plim | Number | 1 | — | Power the pitch controller limits to, in pu of the nominal power. | p_limit |
| Kp | Number | 10 | — | Proportional gain of the pitch controller, degrees per pu of power error. | kp_pitch |
| Ki | Number | 20 | — | Integral gain of the pitch controller, degrees per pu-second of power error. | ki_pitch |
| βmin | Number | 0 | ° (also rad) | Minimum pitch. The controller rests here below rated power. | pitch_min |
| βmax | Number | 45 | ° (also rad) | Maximum pitch. | pitch_max |
| Rate limit | Number | 10 | °/s (also rad/s) | Largest pitch speed of the servo, either direction. | pitch_rate |
| Servo time constant | Number | 0.1 | s (also ms) | Time constant of the first-order pitch servo. 0 makes the servo follow the command at the rate limit. | t_servo |
| Initial pitch | Number | 0 | ° (also rad) | Pitch, and the controller integrator, at t = 0. Set it to the expected operating pitch to start above rated wind without a power overshoot. | pitch0 |
Cp
| Parameter | Type | Default | Units | Description | ID |
|---|---|---|---|---|---|
| c1 | Number | 0.5176 | — | Coefficient c1 of Cp(λ, β) = c1(c2/λi − c3β − c4)e^(−c5/λi) + c6λ. | c1 |
| c2 | Number | 116 | — | Coefficient c2 of the performance coefficient. | c2 |
| c3 | Number | 0.4 | — | Coefficient c3 of the performance coefficient (per degree of pitch). | c3 |
| c4 | Number | 5 | — | Coefficient c4 of the performance coefficient. | c4 |
| c5 | Number | 21 | — | Coefficient c5 of the performance coefficient. | c5 |
| c6 | Number | 0.0068 | — | Coefficient c6 of the performance coefficient. | c6 |
Monitoring
| Parameter | Type | Default | Units | Description | ID |
|---|---|---|---|---|---|
| Monitor power | Choice: Off / On | Off | — | Record the aerodynamic power P (pu of Pnom) as a named observable. | measure_power |
| Monitor pitch | Choice: Off / On | Off | — | Record the blade pitch (degrees) as a named observable. | measure_pitch |
| Monitor Cp | Choice: Off / On | Off | — | Record the performance coefficient Cp as a named observable. | measure_cp |
Signal Names
| Parameter | Type | Default | Units | Description | ID |
|---|---|---|---|---|---|
| Power name | Text | (empty) | — | Observable name for the aerodynamic power. Blank = skip. | power_name |
| Pitch name | Text | (empty) | — | Observable name for the blade pitch. Blank = skip. | pitch_name |
| Cp name | Text | (empty) | — | Observable name for the performance coefficient. Blank = skip. | cp_name |
Observables
| Default name | Kind | Recorded when | Description | ID |
|---|---|---|---|---|
| set by Power name | Signal | Monitor power is on | Aerodynamic power P = kp·(Cp/Cpmax)·(v/vbase)³, pu of the nominal power. | pmech |
| set by Pitch name | Signal | Monitor pitch is on | Blade pitch β in degrees, after the servo and rate limit. | pitch |
| set by Cp name | Signal | Monitor Cp is on | Performance coefficient Cp(λ, β) at the present tip-speed ratio and pitch. | cp |