Transmission Line ​

A transmission line between end A and end B. Its data (PI or Bergeron, single- or three-phase, R/L/C or surge impedance) comes from a Transmission Line Type stored with the circuit; the line itself only sets an optional length override and per-end current monitoring. Use Split line to draw end B as a separate Transmission Line End, for example in another subsystem; splitting changes only the drawing, not the simulation.

Category: Transmission

Ports ​

PortKindSignalNotes
end_aElectrical terminal—Shown when Conductors is 1
end_a3Three-phase terminal—Shown when Conductors is 3
end_bElectrical terminal—Shown when Conductors is 1 and Split is Joined
end_b3Three-phase terminal—Shown when Conductors is 3 and Split is Joined

Parameters ​

Config ​

ParameterTypeDefaultUnitsDescriptionID
Line nameText(empty)—Unique name of this line in the circuit. It names the line's observables and its far end. Filled in automatically when the line is placed.line_name
Line typeText(empty)—The Transmission Line Type this line uses (its R/L/C or surge-impedance data, PI or Bergeron, and conductor count). Pick one of the circuit's types or create a new one.line_type
Override lengthChoice: Off / OnOff—When On, this line uses its own length instead of the type's default length. Only available for types entered per unit length.length_override
Length (km)Number100—This line's length in km, used instead of the type's default length.length
Monitor end A currentChoice: Off / OnOff—When On, end A of the line publishes the current at its pin as an observable. Each end is monitored independently.a_measure_current
End A positive current directionChoice: Into Line / Out of LineInto Line—Sign convention for end A's monitored current. 'Into Line' = positive when current flows from the network into the line at this end; 'Out of Line' = positive when it flows out of the line into the network.a_current_dir
Monitor end B currentChoice: Off / OnOff—When On, end B of the line publishes the current at its pin as an observable. Each end is monitored independently.b_measure_current
End B positive current directionChoice: Into Line / Out of LineInto Line—Sign convention for end B's monitored current. 'Into Line' = positive when current flows from the network into the line at this end; 'Out of Line' = positive when it flows out of the line into the network.b_current_dir

End A Current Monitoring ​

ParameterTypeDefaultUnitsDescriptionID
End A current nameText(empty)A (also kA)Signal name for end A's current. Leave blank to auto-name it after the line. Single-phase only. Pick a unit; the published value is scaled to it.a_current_name
End A phase A current nameText(empty)A (also kA)Signal name for phase A current at end A. Leave blank to skip phase A. Pick a unit; the published value is scaled to it.a_current_name_pa
End A phase B current nameText(empty)A (also kA)Signal name for phase B current at end A. Leave blank to skip phase B. Pick a unit; the published value is scaled to it.a_current_name_pb
End A phase C current nameText(empty)A (also kA)Signal name for phase C current at end A. Leave blank to skip phase C. Pick a unit; the published value is scaled to it.a_current_name_pc

End B Current Monitoring ​

ParameterTypeDefaultUnitsDescriptionID
End B current nameText(empty)A (also kA)Signal name for end B's current. Leave blank to auto-name it after the line. Single-phase only. Pick a unit; the published value is scaled to it.b_current_name
End B phase A current nameText(empty)A (also kA)Signal name for phase A current at end B. Leave blank to skip phase A. Pick a unit; the published value is scaled to it.b_current_name_pa
End B phase B current nameText(empty)A (also kA)Signal name for phase B current at end B. Leave blank to skip phase B. Pick a unit; the published value is scaled to it.b_current_name_pb
End B phase C current nameText(empty)A (also kA)Signal name for phase C current at end B. Leave blank to skip phase C. Pick a unit; the published value is scaled to it.b_current_name_pc

Used in samples ​