Skip to content

Diode Bridge Rectifier (3-phase) ​

Uncontrolled three-phase 6-pulse bridge rectifier (Graetz). Six diodes (three in the positive group, three in the negative group) fed from a single electrical_3ph AC bus, rectifying to dc_pos / dc_neg. All internal diodes share the same forward-voltage drop and on/off resistances. Each internal diode keeps its own piecewise-linear state and registers an in-solve switch evaluator with the Cholesky solver, so the bridge converges within one outer step even when multiple diodes flip simultaneously (stiff zero-crossing handling, needed for inductive DC loads where the freewheel hand-off across diodes must happen instantaneously). Two independent current-monitoring toggles emit the aggregate DC output current, the per-diode currents, or both.

Category: Power Electronics / Rectifiers

Ports ​

PortKindSignalNotes
acThree-phase terminal—
dc_posElectrical terminal—
dc_negElectrical terminal—

Parameters ​

Config ​

ParameterTypeDefaultUnitsDescriptionID
VfNumber0.7—Per-diode forward conduction threshold (V). Applied to every internal diode in the bridge.v_forward
R_onNumber0.05Ω (also kΩ, MΩ)Per-diode conducting (forward-biased) resistance. Pick a unit from the dropdown. Applied to every internal diode.resistance_on
R_offNumber1000000Ω (also kΩ, MΩ)Per-diode blocking (reverse-biased) resistance. Pick a unit from the dropdown. Applied to every internal diode.resistance_off
Measure bridge (DC) currentChoice: Off / OnOff—Emit the aggregate DC output current as a single observable (sum of currents through the upper-group diodes; by KCL at the DC+ rail this equals the current flowing OUT of dc_pos into the external load).measure_bridge_current
DC positive directionChoice: +ve in / +ve out+ve out—Sign convention for this current. '+ve out' (default) is positive when current flows out of dc_pos into the external load. '+ve in' flips the sign.dc_current_dir
Measure per-diode currentsChoice: Off / OnOff—Emit one observable per internal diode (6). Each diode current is signed anode→cathode. Independent of Measure bridge (DC) current — enable both at once when you need both views.measure_diode_currents
Diode positive directionChoice: +ve in / +ve out+ve in—Sign convention for this current. '+ve in' (default) is positive when current flows into each diode at its anode, toward the cathode. '+ve out' flips the sign.device_current_dir

Bridge Current ​

ParameterTypeDefaultUnitsDescriptionID
DC current nameTextI_dc—Signal name for the aggregate DC output current (A). Blank = skip emission.bridge_current_name

Per-Diode Currents ​

ParameterTypeDefaultUnitsDescriptionID
D1 current nameTextI_d1—Signal name for diode D1 branch current (A). Positive-group A-phase diode (ac_a → dc_pos). Blank = skip emission.current_name_d1
D2 current nameTextI_d2—Signal name for diode D2 branch current (A). Positive-group B-phase diode (ac_b → dc_pos). Blank = skip emission.current_name_d2
D3 current nameTextI_d3—Signal name for diode D3 branch current (A). Positive-group C-phase diode (ac_c → dc_pos). Blank = skip emission.current_name_d3
D4 current nameTextI_d4—Signal name for diode D4 branch current (A). Negative-group A-phase diode (dc_neg → ac_a). Blank = skip emission.current_name_d4
D5 current name (3-phase only)Text(empty)—Signal name for diode D5 branch current (A). Negative-group B-phase diode (dc_neg → ac_b). Blank = skip emission.current_name_d5
D6 current name (3-phase only)Text(empty)—Signal name for diode D6 branch current (A). Negative-group C-phase diode (dc_neg → ac_c). Blank = skip emission.current_name_d6

Observables ​

Default nameKindRecorded whenDescriptionID
set by DC current nameSignalMeasure bridge (DC) current is onAggregate DC output current (A). Sum of currents through the positive-group diodes (D1+D2+D3); by KCL at the DC+ rail this equals the current flowing OUT of dc_pos into the external load. Positive out of dc_pos into the external load for '+ve out' (default); the other direction flips the sign.dcCurrent
set by D1 current nameSignalMeasure per-diode currents is onD1 branch current (A, anode → cathode). Positive-group A (ac_a → dc_pos). The direction switch keeps this sign by default and flips it the other way.branchCurrent_0
set by D2 current nameSignalMeasure per-diode currents is onD2 branch current (A). Positive-group B (ac_b → dc_pos). The direction switch keeps this sign by default and flips it the other way.branchCurrent_1
set by D3 current nameSignalMeasure per-diode currents is onD3 branch current (A). Positive-group C (ac_c → dc_pos). The direction switch keeps this sign by default and flips it the other way.branchCurrent_2
set by D4 current nameSignalMeasure per-diode currents is onD4 branch current (A). Negative-group A (dc_neg → ac_a). Positive into each diode at its anode, toward the cathode for '+ve in' (default); the other direction flips the sign.branchCurrent_3
set by D5 current name (3-phase only)SignalMeasure per-diode currents is onD5 branch current (A). Negative-group B (dc_neg → ac_b). Positive into each diode at its anode, toward the cathode for '+ve in' (default); the other direction flips the sign.branchCurrent_4
set by D6 current name (3-phase only)SignalMeasure per-diode currents is onD6 branch current (A). Negative-group C (dc_neg → ac_c). Positive into each diode at its anode, toward the cathode for '+ve in' (default); the other direction flips the sign.branchCurrent_5

Used in samples ​